MID222 Volvo FH retarder control unit fault codes

By |

MID222 Volvo FH retarder control unit fault codes

See also:

 

MID 222 PID 110

Parameter:

Coolant temperature

Fault:

FMI 0   High fluid temperature. Insufficient cooling of the moderator or movement on hilly terrain with frequent use of the moderator.

FMI 4   Shorting the signal wire in the temperature sensor circuit to ground.

FMI 5   Shorting the signal wire in the temperature sensor circuit to ground or to a higher voltage.

FMI 13   Faulty retarder control unit.

MID 222 PID 119

Parameter:

Coolant pressure

Fault:

FMI 0   The voltage on the retarder unit from the sensor is between 3.6 and 4.6 V. The sensor is defective, the moderator cooling circuit is damaged or blocked.

FMI 3   The voltage on the retarder unit from the sensor is higher than 4.6 V. Closure of the wiring in the sensor circuit to a higher voltage or the sensor is faulty.

FMI 4   The voltage on the retarder unit from the sensor is below 0.4 V. The wiring in the sensor circuit is faulty or the sensor is faulty.

MID 222 PID 120

Parameter:

Oil temperature

Fault:

FMI 0   High oil temperature. Insufficient cooling of the moderator or movement on hilly terrain with frequent use of the moderator.

FMI 4   Shorting the signal wire in the temperature sensor circuit to ground.

FMI 5   Shorting the signal wire in the temperature sensor circuit to ground or to a higher voltage.

FMI 13   Faulty retarder control unit.

MID 222 PID 158

Parameter:

Decelerator Power Supply Voltage

Fault:

FMI 0   The supply voltage is above 33 V. The generator is faulty or the device for fast charging of batteries is connected without disconnecting from the car.

FMI 1   The supply voltage is below 18 V for a few seconds after starting the engine. Low battery charge, poor contact on power cable or ground.

MID 222 SID 2

Parameter:

Valve PWM retarder

Fault:

FMI 3   A short circuit in the PWM valve circuit to a higher voltage or the PWM valve is faulty.

FMI 4   A short in the PWM valve circuit is shorted to ground or the PWM valve is faulty.

FMI 5   An open circuit in the PWM valve or a PWM valve is faulty.

FMI 6   A short in the PWM valve circuit is shorted to ground or the PWM valve is faulty.

MID 222 SID 221

Parameter:

Pressure sensor power supply

Fault:

FMI 1   The voltage is between 0.5 and 4.5 V. The wiring in the sensor circuit is faulty or the sensor is faulty.

FMI 3   Voltage is higher than 5.5 V. Short circuit of wires between the pressure sensor and the moderator control unit to a higher voltage.

FMI 4   Faulty retarder control unit.

MID 222 SID 231

Parameter:

SAE J1939 data feed

Fault:

FMI 2   A large number of erroneous messages on the data channel. Breakage or partial damage to the data channel wires. Oxidized or damaged contacts in the connectors.

MID 222 SID 240

Parameter:

Program memory

Fault:

FMI 2   Software Error. The retarder control unit is not programmed or programmed with errors.

MID 222 SID 250

Parameter:

SAE J1708 data feed

Fault:

FMI 2   A large number of erroneous messages on the data channel. Breakage or partial damage to the data channel wires. Oxidized or damaged contacts in the connectors.

FMI 4   The retarder control unit cannot read the voltage change values. The closure of the data channel wires to ground.

FMI 9   Skipped a few messages on the data channel. The moderator control unit is in the process of programming, the data channel wiring is damaged or the contacts in the connectors are oxidized.

MID 222 SID 253

Parameter:

Gauge memory, EEPROM

Fault:

FMI 2   Software Error. Re-program the retarder control unit.

MID 222 PPID 30

Parameter:

Valve PWM retarder

Fault:

FMI 13   Incorrect calibration value of the PWM valve in the retarder control unit. Replace control unit.

MID 222 PPID 31

Parameter:

Air pressure

Fault:

FMI 0   The air pressure in the moderator is above 4.6 Bar . PWM valve defective.

FMI 3   High voltage in the circuit between the moderator unit and the pressure sensor. Shorting the signal or supply wire of the sensor to a higher voltage. The pressure sensor may be faulty.

FMI 5   An open in the sensor circuit or a short to ground in the sensor circuit.

MID 222 PPID 34

Parameter:

Voltage +12 V. control unit (used to power the internal circuits of the control unit)

Fault:

FMI 0   The voltage is too high. Faulty wiring.

FMI 1   Voltage too low. Short to ground.

MID 222 PPID 54

Parameter:

Voltage +5 V. (used to power the air pressure sensor)

Fault:

FMI 0   The voltage is too high. Short circuit to higher voltage.

FMI 1   Voltage too low. Short to ground.

MID 222 PPID 55

Parameter:

Retarder control unit temperature

Fault:

FMI 0   The temperature of the retarder control unit is too high. Possible heat from an external heat source.

MID 222 PPID 210

Parameter:

Valve PWM retarder

Fault:

FMI 3   Shorting the wires in the PWM valve circuit to a higher voltage or the PWM valve is faulty.

FMI 5   An open wire in the PWM valve circuit or a PWM valve is faulty.

FMI 6   Short circuit of wires in the circuit of the PWM valve to the ground or defective PWM valve.

MID 222 PSID 1

Parameter:

Power Relay K05

Fault:

FMI 3   Short circuit of the relay control wire to a higher voltage.

FMI 6   Short circuit of relay control wire to earth or relay malfunction.

MID 222 PSID 201

Parameter:

Data Link Disruption SAE J1939 with car control unit MID144

Fault:

FMI 9   The retarder control unit MID222 does not receive signals from the car control unit MID144 via the SAE J1939 data channel. Broken or partial damage to data wire between the blocks.

MID 222 PSID 204

Parameter:

Data Link Disruption SAE J1939 with MID136 braking system control unit

Fault:

FMI 9   The retarder control unit MID222 does not receive signals from the MID136 braking system control unit via the SAE J1939 data channel. Broken or partial damage to data wire between the blocks.

MID 222 PSID 254

Parameter:

DIEE signal

Fault:

FMI 3   Shorting the signal wire to a higher voltage.

 

 