MID214 Volvo burglar alarm control unit fault codes
See also:
- MID206 Volvo CD and Radio Player Fault Codes
- MID185 Fault codes for Volvo APM Air Dryer Control Units
MID 214 SID 240
Parameter:
Program memory
Fault:
FMI 2 Software failure or electromagnetic interference.
MID 214 SID 254
Parameter:
Control block
Fault:
FMI 12 Software failure or electromagnetic interference.
MID 214 PSID 6
Parameter:
Motion Sensor
Fault:
FMI 11 Motion sensors are closed with foreign objects, an open or short circuit of the sensor wires, oxidation of contacts in the connectors, a motion sensor is faulty.
MID 214 PSID 7
Parameter:
Siren
Fault:
FMI 9 The connection between the unit and the siren is interrupted. Siren is not connected, wire is broken or short-circuited, contacts in connectors are oxidized or damaged. Siren may be faulty.
FMI 12 The alarm control unit has detected a fault in the siren. The siren has failed due to mechanical damage or environmental influences. Possible poor battery condition inside the siren.
MID 214 PSID 8
Parameter:
Relay starter K03
Fault:
FMI 4 Shorting the wire between the relay and the control unit alarm to ground.
MID 214 PSID 10
Parameter:
Door lock control unit
Fault:
FMI 12 Loss of contact between the alarm control unit and the door lock control unit. Short circuit of wires between blocks on power supply or on weight. Breakage of wires between the blocks or defective control unit door locks.