MID214 Volvo burglar alarm control unit fault codes

By |

MID214 Volvo burglar alarm control unit fault codes

See also:

 

MID 214 SID 240

Parameter:

Program memory

Fault:

FMI 2   Software failure or electromagnetic interference.

MID 214 SID 254

Parameter:

Control block

Fault:

FMI 12   Software failure or electromagnetic interference.

MID 214 PSID 6

Parameter:

Motion Sensor

Fault:

FMI 11   Motion sensors are closed with foreign objects, an open or short circuit of the sensor wires, oxidation of contacts in the connectors, a motion sensor is faulty.

MID 214 PSID 7

Parameter:

Siren

Fault:

FMI 9   The connection between the unit and the siren is interrupted. Siren is not connected, wire is broken or short-circuited, contacts in connectors are oxidized or damaged. Siren may be faulty.

FMI 12   The alarm control unit has detected a fault in the siren. The siren has failed due to mechanical damage or environmental influences. Possible poor battery condition inside the siren.

MID 214 PSID 8

Parameter:

Relay starter K03

Fault:

FMI 4   Shorting the wire between the relay and the control unit alarm to ground.

MID 214 PSID 10

Parameter:

Door lock control unit

Fault:

FMI 12   Loss of contact between the alarm control unit and the door lock control unit. Short circuit of wires between blocks on power supply or on weight. Breakage of wires between the blocks or defective control unit door locks.

 

 